{"id":42005,"date":"2021-09-10T13:51:01","date_gmt":"2021-09-10T13:51:01","guid":{"rendered":"https:\/\/conduct.nl\/emc-zoning-concept\/"},"modified":"2025-10-16T16:36:39","modified_gmt":"2025-10-16T14:36:39","slug":"concept-de-zones-cem","status":"publish","type":"post","link":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/","title":{"rendered":"Concept de zones CEM"},"content":{"rendered":"<p data-start=\"331\" data-end=\"403\"><strong>Concept de zones CEM pour les installations photovolta\u00efques<\/strong><\/p>\n<p data-start=\"405\" data-end=\"730\">Le concept de zones CEM (<em data-start=\"430\" data-end=\"463\">Compatibilit\u00e9 \u00c9lectromagn\u00e9tique<\/em>) divise une installation en zones de protection contre la foudre (LPZ). Chaque zone repr\u00e9sente un niveau d\u2019exposition diff\u00e9rent aux courants de foudre et aux inductions \u00e9lectromagn\u00e9tiques. Pour les syst\u00e8mes PV, les d\u00e9finitions et mesures suivantes s\u2019appliquent :<\/p>\n<p>&nbsp;<\/p>\n<p data-start=\"732\" data-end=\"778\"><strong>LPZ 0A &#8211; Zone ext\u00e9rieure non prot\u00e9g\u00e9e<\/strong><\/p>\n<p data-start=\"779\" data-end=\"954\">Il s\u2019agit de la zone o\u00f9 est install\u00e9e l\u2019installation PV, par exemple sur le toit. En l\u2019absence de syst\u00e8me de protection contre la foudre (LPS), le syst\u00e8me est expos\u00e9 \u00e0\u202f:<\/p>\n<ul data-start=\"955\" data-end=\"1059\">\n<li data-start=\"955\" data-end=\"991\">\n<p data-start=\"957\" data-end=\"991\">Des impacts directs de la foudre ;<\/p>\n<\/li>\n<li data-start=\"992\" data-end=\"1059\">\n<p data-start=\"994\" data-end=\"1059\">Des courants de foudre int\u00e9graux sur les c\u00e2bles et les onduleurs.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1061\" data-end=\"1074\">Dans ce cas :<\/p>\n<ul data-start=\"1075\" data-end=\"1353\">\n<li data-start=\"1075\" data-end=\"1133\">\n<p data-start=\"1077\" data-end=\"1133\">Un parafoudre de Type 1 doit \u00eatre install\u00e9 c\u00f4t\u00e9 DC ;<\/p>\n<\/li>\n<li data-start=\"1134\" data-end=\"1234\">\n<p data-start=\"1136\" data-end=\"1234\">Cela s\u2019applique \u00e9galement si un LPS est pr\u00e9sent et connect\u00e9 physiquement \u00e0 l\u2019installation PV ;<\/p>\n<\/li>\n<li data-start=\"1235\" data-end=\"1353\">\n<p data-start=\"1237\" data-end=\"1353\">Une liaison \u00e9quipotentielle doit \u00eatre \u00e9tablie entre le LPS externe et le point de mise \u00e0 la terre de l\u2019onduleur.<\/p>\n<p>&nbsp;<\/li>\n<\/ul>\n<p data-start=\"1355\" data-end=\"1397\"><strong>LPZ 0B &#8211; Zone ext\u00e9rieure prot\u00e9g\u00e9e<\/strong><\/p>\n<p data-start=\"1398\" data-end=\"1517\">Zone situ\u00e9e dans l\u2019angle de protection des pointes de captage, sans connexion conductrice directe \u00e0 l\u2019installation PV :<\/p>\n<ul data-start=\"1518\" data-end=\"1639\">\n<li data-start=\"1518\" data-end=\"1557\">\n<p data-start=\"1520\" data-end=\"1557\">Prot\u00e9g\u00e9e contre les impacts directs ;<\/p>\n<\/li>\n<li data-start=\"1558\" data-end=\"1639\">\n<p data-start=\"1560\" data-end=\"1639\">Isol\u00e9e \u00e9lectriquement du LPS gr\u00e2ce \u00e0 une distance de s\u00e9paration suffisante.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1641\" data-end=\"1745\">\u2192 Seules des surtensions induites peuvent appara\u00eetre ici.<br data-start=\"1698\" data-end=\"1701\" \/>\u2192 Un parafoudre de Type 2 est suffisant.<\/p>\n<p>&nbsp;<\/p>\n<p data-start=\"1747\" data-end=\"1787\"><strong data-start=\"1752\" data-end=\"1787\">LPZ 1 &#8211; Infrastructure entrante<\/strong><\/p>\n<p data-start=\"1788\" data-end=\"1822\">Zone de transition dans laquelle :<\/p>\n<ul data-start=\"1823\" data-end=\"1982\">\n<li data-start=\"1823\" data-end=\"1906\">\n<p data-start=\"1825\" data-end=\"1906\">Le courant de foudre est partiellement r\u00e9parti via le LPS et la mise \u00e0 la terre ;<\/p>\n<\/li>\n<li data-start=\"1907\" data-end=\"1982\">\n<p data-start=\"1909\" data-end=\"1982\">Des parafoudres suppl\u00e9mentaires sont install\u00e9s \u00e0 la fronti\u00e8re de la zone.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1984\" data-end=\"2070\">Si l\u2019installation PV est situ\u00e9e en LPZ 0B et l\u2019onduleur en int\u00e9rieur (LPZ 2) :<\/p>\n<ul data-start=\"2071\" data-end=\"2123\">\n<li data-start=\"2071\" data-end=\"2123\">\n<p data-start=\"2073\" data-end=\"2123\">Un parafoudre de Type 2 c\u00f4t\u00e9 DC est suffisant.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2125\" data-end=\"2231\">Cependant, en cas de liaison physique avec la zone LPZ 0A (ex. : ch\u00e2ssis m\u00e9tallique raccord\u00e9 au LPS) :<\/p>\n<ul data-start=\"2232\" data-end=\"2275\">\n<li data-start=\"2232\" data-end=\"2275\">\n<p data-start=\"2234\" data-end=\"2275\">Un parafoudre de Type 1+2 est requis.<\/p>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p data-start=\"2277\" data-end=\"2317\"><strong>LPZ 2 &#8211; Int\u00e9rieur de l\u2019onduleur<\/strong><\/p>\n<p data-start=\"2318\" data-end=\"2381\">Zone interne prot\u00e9g\u00e9e par le bo\u00eetier m\u00e9tallique de l\u2019onduleur :<\/p>\n<ul data-start=\"2382\" data-end=\"2509\">\n<li data-start=\"2382\" data-end=\"2431\">\n<p data-start=\"2384\" data-end=\"2431\">Prot\u00e8ge davantage contre les courants induits ;<\/p>\n<\/li>\n<li data-start=\"2432\" data-end=\"2509\">\n<p data-start=\"2434\" data-end=\"2509\">Des parafoudres suppl\u00e9mentaires permettent de r\u00e9duire l\u2019\u00e9nergie r\u00e9siduelle.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2511\" data-end=\"2594\">\u2192 Les parafoudres doivent \u00eatre install\u00e9s <strong data-start=\"2552\" data-end=\"2593\">aussi pr\u00e8s que possible de l\u2019onduleur<\/strong>.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"img-responsive img-responsive alignnone wp-image-3754 size-large img-responsive i\" title=\"EMC zoneconcept\" src=\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11-1024x414.png\" alt=\"EMC zoneconcept\" width=\"1024\" height=\"414\" srcset=\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11-1024x414.png 1024w, https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11-600x243.png 600w, https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11-300x121.png 300w, https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11-768x311.png 768w, https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Schermafbeelding-2021-10-11-om-14.09.11.png 1179w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Avez-vous des questions concernant le concept de zone CEM ? N&#8217;h\u00e9sitez pas \u00e0 <a href=\"http:\/\/conduct.nl\/fr\/contact\/\">nous contacter<\/a>.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Concept de zones CEM pour les installations photovolta\u00efques Le concept de zones CEM (Compatibilit\u00e9 \u00c9lectromagn\u00e9tique) divise une installation en zones de protection contre la foudre (LPZ). Chaque zone repr\u00e9sente un niveau d\u2019exposition diff\u00e9rent aux courants de foudre et aux inductions \u00e9lectromagn\u00e9tiques. Pour les syst\u00e8mes PV, les d\u00e9finitions et mesures suivantes s\u2019appliquent : &nbsp; LPZ 0A &hellip;<\/p>\n","protected":false},"author":7,"featured_media":41989,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2327,2160],"tags":[],"class_list":["post-42005","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aarding-en-potentiaalvereffening-fr","category-bliksem-en-overspanningsbeveiliging-fr"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Concept de zones CEM | Conduct Technical Solutions BV<\/title>\n<meta name=\"description\" content=\"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Concept de zones CEM | Conduct Technical Solutions BV\" \/>\n<meta property=\"og:description\" content=\"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\" \/>\n<meta property=\"og:site_name\" content=\"Conduct\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-10T13:51:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-16T14:36:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricardo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ricardo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\"},\"author\":{\"name\":\"Ricardo\",\"@id\":\"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8\"},\"headline\":\"Concept de zones CEM\",\"datePublished\":\"2021-09-10T13:51:01+00:00\",\"dateModified\":\"2025-10-16T14:36:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\"},\"wordCount\":403,\"image\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png\",\"articleSection\":[\"Mise \u00e0 la terre et \u00e9quipotentialit\u00e9\",\"Protection contre la foudre et les surtensions\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\",\"url\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\",\"name\":\"Concept de zones CEM | Conduct Technical Solutions BV\",\"isPartOf\":{\"@id\":\"https:\/\/conduct.nl\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png\",\"datePublished\":\"2021-09-10T13:51:01+00:00\",\"dateModified\":\"2025-10-16T14:36:39+00:00\",\"author\":{\"@id\":\"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8\"},\"description\":\"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!\",\"breadcrumb\":{\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage\",\"url\":\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png\",\"contentUrl\":\"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png\",\"width\":1500,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/conduct.nl\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Concept de zones CEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/conduct.nl\/#website\",\"url\":\"https:\/\/conduct.nl\/\",\"name\":\"Conduct\",\"description\":\"Conduct Technical Solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/conduct.nl\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8\",\"name\":\"Ricardo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/conduct.nl\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1bc40502937d556b6349b78444c696078ca24bd7e391c2d9a22ed13f303b4bf1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1bc40502937d556b6349b78444c696078ca24bd7e391c2d9a22ed13f303b4bf1?s=96&d=mm&r=g\",\"caption\":\"Ricardo\"},\"url\":\"https:\/\/conduct.nl\/fr\/author\/1627045716452\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Concept de zones CEM | Conduct Technical Solutions BV","description":"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/","og_locale":"fr_FR","og_type":"article","og_title":"Concept de zones CEM | Conduct Technical Solutions BV","og_description":"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!","og_url":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/","og_site_name":"Conduct","article_published_time":"2021-09-10T13:51:01+00:00","article_modified_time":"2025-10-16T14:36:39+00:00","og_image":[{"width":1500,"height":500,"url":"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png","type":"image\/png"}],"author":"Ricardo","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Ricardo","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#article","isPartOf":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/"},"author":{"name":"Ricardo","@id":"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8"},"headline":"Concept de zones CEM","datePublished":"2021-09-10T13:51:01+00:00","dateModified":"2025-10-16T14:36:39+00:00","mainEntityOfPage":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/"},"wordCount":403,"image":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage"},"thumbnailUrl":"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png","articleSection":["Mise \u00e0 la terre et \u00e9quipotentialit\u00e9","Protection contre la foudre et les surtensions"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/","url":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/","name":"Concept de zones CEM | Conduct Technical Solutions BV","isPartOf":{"@id":"https:\/\/conduct.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage"},"image":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage"},"thumbnailUrl":"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png","datePublished":"2021-09-10T13:51:01+00:00","dateModified":"2025-10-16T14:36:39+00:00","author":{"@id":"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8"},"description":"Concept de zone CEM : que signifie r\u00e9ellement CEM ? CEM signifie Compatibilit\u00e9 \u00c9lectromagn\u00e9tique. En savoir plus ici\u202f!","breadcrumb":{"@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#primaryimage","url":"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png","contentUrl":"https:\/\/conduct.nl\/app\/uploads\/2021\/09\/Banner_algemeen.png","width":1500,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/conduct.nl\/fr\/concept-de-zones-cem\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/conduct.nl\/fr\/"},{"@type":"ListItem","position":2,"name":"Concept de zones CEM"}]},{"@type":"WebSite","@id":"https:\/\/conduct.nl\/#website","url":"https:\/\/conduct.nl\/","name":"Conduct","description":"Conduct Technical Solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/conduct.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Person","@id":"https:\/\/conduct.nl\/#\/schema\/person\/60ebffdd7bf2f7257cf22cd582bbf9b8","name":"Ricardo","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/conduct.nl\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1bc40502937d556b6349b78444c696078ca24bd7e391c2d9a22ed13f303b4bf1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1bc40502937d556b6349b78444c696078ca24bd7e391c2d9a22ed13f303b4bf1?s=96&d=mm&r=g","caption":"Ricardo"},"url":"https:\/\/conduct.nl\/fr\/author\/1627045716452\/"}]}},"_links":{"self":[{"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/posts\/42005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/comments?post=42005"}],"version-history":[{"count":8,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/posts\/42005\/revisions"}],"predecessor-version":[{"id":47078,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/posts\/42005\/revisions\/47078"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/media\/41989"}],"wp:attachment":[{"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/media?parent=42005"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/categories?post=42005"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/conduct.nl\/fr\/wp-json\/wp\/v2\/tags?post=42005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}